Close

EmailProduct Enquiry - Duct Burners - CD Series

Duct Burners - CD Series  
Thank you for your interest. We will get back to you soon
   
Duct-Burners-CD Series

Duct Burners - CD Series

This series includes burners with compact design and easy maintenance.  The proportional control method is adopted for the adjustment of the gas combustion to ensure stable operation and proper temperature control.


Salient Features

Safe Design:

  • No possibility of back fire due to adoption of pre-mixture combustion method
  • Design safety is based on The Technology Indication on combustion given by the Japan Gas Association

Space saving and easy maintenance:

  • The blower for combustion and the gas piping etc are installed on the upper part of the main body and thus it contributes to space saving
  • The window to observe combustion condition and the inspection door are installed. The latter is of hinged type, enabling easy inspection and maintenance of inside part

Stable operation and temperature control:

  • The burner possesses a strategic construction which gives an excellent stability of combustion
  • The proportional control method is adopted for the adjustment of the gas combustion and proper temperature control becomes available. (On-Off & High - low - off control modes are also available)

Download Duct Burners CD Series Brochure  Submit

Specification

MODEL Capacity (Kcal/h) Fuel consumption (m3/h)- LPG Fuel gas pressure (mmWC)-LPG Voltage / Phase Motor KW Duct cross section (mm) Combustion method Connecting pipe diameter(inch)-LPG Turn down ratio
CD-50PW 50,000 2.1 280 220 v / 1Ø 0.25 500*320

PRE-MIXING

1/2 1:3
CD-100PW 100,000 4.2 280 220 v / 1Ø 0.25 700*500 1/2 1:5
CD-200PW 200,000 8.3 280 400 v / 3Ø 0.4 950*700 1/2 1:10
CD-300PW 300,000 12.5 280 400 v / 3Ø 0.75 1100*900 3/4 1:10
CD-400PW 400,000 16.7 280 400 v / 3Ø 0.75 1300*1000 1 1:10
CD-500PW 500,000 20.8 280 400 v / 3Ø 1.5 1500*1100 1-1/4 1:10
CD-600PW 600,000 25 280 400 v / 3Ø 1.5 1100*900 1-1/2 1:10
CD-700PW 700,000 29.2 280 400 v / 3Ø 2.2 1400*1100 1-1/2 1:10
CD-800PW 800,000 33.3 280 400 v / 3Ø 2.2 1400*1100 2 1:10
CD-900PW 900,000 37.5 280 400 v / 3Ø 3.7 1550*1150 2 1:10
CD1000PW 1,000,000 41.7 280 400 v / 3Ø 3.7 1550*1150 2 1:10

Fuel Input Conditions:


Dimension
Duct Burners - CD Series - Dimension

Model A B C D E F G H I J (LPG)
CD-50PW 650 470 1000 500 320 75 75 920 335 690
CD-100PW 850 650 1000 700 500 75 75 1100 425 870
CD-200PW 1100 850 1000 950 700 75 75 1300 525 1070
CD-300PW 1250 1050 1200 1100 900 75 75 1540 625 1270
CD-400PW 1450 1150 1300 1300 1000 75 75 1680 675 1390
CD-500PW 1650 1250 1400 1500 1100 75 75 1780 725 1490
CD-600PW 1300 1100 1400 1100 900 100 100 1700 650 1620
CD-700PW 1600 1300 1500 1400 1100 100 100 1900 750 1820
CD-800PW 1600 1300 1500 1400 1100 100 100 1900 750 1820
CD-900PW 1750 1350 1800 1550 1150 100 100 2070 775 1870
CD-1000PW 1750 1350 1800 1550 1150 100 100 2070 775 1930